0.3KG Throat Swab Coronavirus Test Kit Clinical Performance

Wuxi Owgels Medical Instruments Co., Ltd
Contact Now

0.3KG Throat Swab Coronavirus Test Kit Clinical Performance

Certification : CE; ISO

Place of Origin : Beijing

MOQ : 10-100pcs

Price : negotiable

Supply Ability : 1million per week

Delivery Time : 3-5working days

Packaging Details : 25pcs per case

Specificity : 100%

Overall Agreement : 97.5%

Sample Type : Nasal/Throat Swab

Assay Incubation : 15minutes, RT

Format : 25T/Kit

N.W. : 0.3KG

Number of Box : 50Kits

Contact Now

COVID-19 Antigen Rapid Test Kit Clinical Performance of Antigen Test for fresh swabs

PERFORMANCE CHARACTERCS

The assay demonstrated excellent clinical specificity 100% (95% CI: 98.12%-100%). Overall Agreement was 96.21% (93.34%-97.87%).

1. Clinical Performance of Antigen Test for fresh swabs

Using 127 fresh NP swabs which were collected freshly in Extraction Buffer in the kit to evaluate the Clinical performance of the COVID-19 Antigen Rapid Test Kit. 67 Patients who presented within 7 days of symptom onset and 60 normal persons were included in the initial primary evaluation. The Result is below:

Sansure Covid-19 RT-PCR Assay
Positive Negative Total
Kewei COVID-19 Antigen Rapid Assay Positive 64 0 64
Negative 3 60 63
Total 67 60 127

The assay demonstrated acceptable clinical sensitivity for fresh swab samples is 95.52% (95% CI: 87.64%-98.47%) when compared to a molecular device produced by Sansure Inc. The assay demonstrated excellent clinical specificity 100% (95% CI: 93.98%-100%). Overall Agreement was 97.64% (93.28%-99.19%).

2. Overall Clinical Performance of Antigen Test Kit

A total of above 157 positive samples and 260 negative samples were detected to evaluate the clinical performance of the COVID-19 Antigen Rapid Test Kit. The Result is below:

Sansure Covid-19 RT-PCR Assay
Positive Negative Total
Kewei COVID-19 Antigen Rapid Assay Positive 143 0 143
Negative 14 260 274
Total 157 260 417

The assay demonstrated acceptable total clinical sensitivity is 91.08% (95% CI: 85.59%-94.61%) when compared to a molecular device produced by Sansure Inc. The assay demonstrated excellent clinical specificity 100% (95% CI: 98.54%-100%). Overall Agreement was 96.64% (94.44%-97.99%).

4. Limit of Detection(LoD)

Limit of detection (LoD) was determined by evaluating different concentrations of heat inactivated SARS-CoV-2 virus. LoD of the SARS-CoV-2 antigen rapid kit was confirmed as 38.5 TCID50/ml.

5. High-dose Hook effect

No high dose hook effect was observed when test with up to a concentration of 6.3×105 TCID50/ml of heat inactive SARS-CoV-2 virus from Academy of Military Sciences PLA China.

6. Cross Reactivity

Many types of pneumonia are companied by fever, cough and other respiratory symptoms. In order to eliminate similar clinical symptoms of other types of pneumonia effects, pneumonia mycoplasma, influenza A, pneumococcus etc. were detected for the specific assessment. Each of the organism and viruses were tested in the absence or presence of heat inactivated SARS-CoV-2 virus(308TCID 50/ml), No cross-reactivity or interference was seen.

0.3KG Throat Swab Coronavirus Test Kit Clinical Performance

0.3KG Throat Swab Coronavirus Test Kit Clinical Performance

0.3KG Throat Swab Coronavirus Test Kit Clinical Performance

0.3KG Throat Swab Coronavirus Test Kit Clinical Performance


Product Tags:

25T/Kit Coronavirus Test Kit

      

0.3KG Coronavirus Test Kit

      

Throat Swab Coronavirus Test Kit

      
Quality 0.3KG Throat Swab Coronavirus Test Kit Clinical Performance for sale

0.3KG Throat Swab Coronavirus Test Kit Clinical Performance Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuxi Owgels Medical Instruments Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0